Special Transformers

Indoor / Outdoor installation

Special Transformers

Special transformers are used in special applications in the industry and in the grid. These transformers are produced with special focus deal with over currents, over voltages and reactive loads under severe conditions. Special transformers are regarded as the peak of transformer industry due to know-how, diligence and accuracy required by both design and production technology. Haritha Transformers manufacture a wide range of special transformers up to 5 MVA with voltage class 36 kV.

Furnace Transformers

Furnace transformers are used in iron and steel plants for melting metal. The metal in melting pot is melted with very high currents.


Additional measures shall be taken in furnace transformers against these high currents, possible short circuits and over currents.

Earthing Transformers

Earthing transformers are used for creating a neural point that can be connected to the ground for systems fed with delta connected coil.

 

They are not only used for grounding, but also can be used to provide output for the service needs too.

Isolation Transformers

Isolation transformers are used for Protecting from damage or interface caused by electrical noise and spikes.

No. of Phases: 1-Ø or 3-Ø

Input to Output Ratio: 1:1
Line Frequency: 45 to 65 Hertz

Multi-Winding Transformers

Multi-Winding transformers have more than one winding and are used in SOLAR / WIND / INDUSTRIAL applications

 

Multiple Winding Transformers generally have one single primary winding with two or more secondary windings. But the beauty of these transformers is that they allow us to have more than just one winding in either the primary or secondary side.

 

The principal of operation of a multiple winding transformer is no different from that of an ordinary transformer. Primary and secondary voltages, currents and turns ratios are all calculated the same, the difference this time is that we need to pay special attention to the voltage polarities of each coil winding, the dot convention marking the positive (or negative) polarity of the winding, when we connect them together.

 

Multiple Winding Transformers can also be used to provide either a step-up, a step-down, or a combination of both between the various windings. In fact, multiple winding transformers can have several secondary windings on the same core with each one providing a different voltage or current level output.

 

Range: Up to 2.5 MVA in 11 kV, 22 kV & 33 kV configurations in Step Up Configuration of 3, 4 & 5 Winding Application.

Contact
Haritha Transformers manufacture

a wide range of medium power transformers up to 5MVA with voltage class 36 kV.

+91 - 93351 99999